Software Model Number
Model | Description | Software Model Number |
DFUW, DUWC, VUWC | 24 inch Wine Cellar | 11 |
DFUR, DUAR, VUAR | 24 inch Beverage Center | 21 |
DFRD, DURD, VURD | 24 inch Refrigerated Drawers | 16 |
Viking Refrigerator Diagnostic Details
Solution Diagnostics Mode enables you to determine the firmware and also software application versions, test standing of “model details” system parts and also sensing units, as well as transform state of elements where appropriate (i.e.– compressor on/off, and so on.).
Enabling Service Setting: To enable Solution Setting, press and also hold the “WARMER” switch while pushing the “COLDER” button 4 times within five secs.
- You can not make it possible for Service Mode while in Set Setting. – All system functions will remain in their existing state while in Service Setting.
- Alarms are impaired during Solution Mode and reset after exiting Solution Setting.
- Service Mode will instantly disable after five (5) mins of no keypad access
After getting in Service Setting, the very first number that you will see suggests the software design number for the particular device you are servicing. For instance, if you are servicing a 24 inch wine cellar (DFUW, DUWC, VUWC), the initial number you will certainly see is 11. See graph listed below for corresponding design as well as software application reference.
The 2nd number you will certainly see indicates the software application version release. As an example, if you see 44 on the screen panel it suggests software application version 4.4.
Diagnostics:
While in Service Mode, press the “COLLECTION” switch to tip with Tests 0-9. The initial figure of the display will show the test number. The second digit shows the current state of each element under test as well as is presented as “1” being ON, CLOSED, or SHORTED and “0” being OFF or OPEN. Examinations 0 and also 1 expose an open or shorted condition discovered at the sensing unit inputs. Examinations 2 through 6 allow you to transform loads ON with the “WARMER” switch as well as OFF with the “COLDER” button. Tests 7 with 9 confirm state change of the door switches over and/or magnetic reed sensing unit. The element examinations readily available are described in Available Element Examinations graph.
PROBLEM | POSSIBLE CAUSE | WHAT TO DO |
Refrigerator still won’t operate | Refrigerator is malfunctioning | Unplug refrigerator and transfer food to another refrigerator. If another refrigerator is not available, place dry ice in freezer section to preserve food. Warranty does not cover food loss. Contact service for assistance. |